Scope

FPrimeC Solutions was hired by EXP Services Inc. to perform Nondestructive Evaluation of Parking Garage at CF Toronto Eaton Centre, Toronto, Ontario. The area under investigation was a concrete slab along the entrance ramp of the parking facilities.

The main objective of the project was to verify the thickness of concrete slab using Impact-Echo method, assess structural integrity, and determine the likelihood of active corrosion using Half-Cell Corrosion Potential Mapping.

Solution: Nondestructive Evaluation of Parking Garage

Two areas are under investigation are located at the entrance and exit ramps. The ramp elements are reinforced concrete slabs with asphalt topping. Asphalt was removed prior to testing concrete surface. Different nondestructive evaluation tools were used to assess the two areas. A systematic grid was designed, and tests were conducted on each and every grid point.

1- Impact-Echo

Impact-Echo test was used to verify the thickness of concrete slab, and to verify the structural integrity of the slab. A total of 192 test point locations were identified for Area 1 and 18 points for Area 2. The test help identify potential delamination across the slab.

2- Half-cell Corrosion Potential

Half-Cell corrosion potential mapping was used to determine the likelihood of active corrosion in the area. The test helps identify the locations where the likelihood of corrosion is high.

 